c11 tolerance (shaft, IT11)

Shaft tolerance class c11 per ISO 286-1:2010: fundamental deviation es −60 … −480, grade IT11 (60 µm at ≤ 3 mm to 400 µm at 400–500 mm). For an exact size, open the calculator with c11 selected.

Type
Shaft
Grade
IT11
Tolerance
60 … 400 µm
Fund. deviation
es −60 … −480 µm

c11 limits by size range

Size (mm)Upper (µm)Lower (µm)Ø max (mm)Ø min (mm)
≤ 3−60−1202.9402.880
3 – 6−70−1455.9305.855
6 – 10−80−1709.9209.830
10 – 14−95−20513.90513.795
14 – 18−95−20517.90517.795
18 – 24−110−24023.89023.760
24 – 30−110−24029.89029.760
30 – 40−120−28039.88039.720
40 – 50−130−29049.87049.710
50 – 65−140−33064.86064.670
65 – 80−150−34079.85079.660
80 – 100−170−39099.83099.610
100 – 120−180−400119.820119.600
120 – 140−200−450139.800139.550
140 – 160−210−460159.790159.540
160 – 180−230−480179.770179.520
180 – 200−240−530199.760199.470
200 – 225−260−550224.740224.450
225 – 250−280−570249.720249.430
250 – 280−300−620279.700279.380
280 – 315−330−650314.670314.350
315 – 355−360−720354.640354.280
355 – 400−400−760399.600399.240
400 – 450−440−840449.560449.160
450 – 500−480−880499.520499.120

Deviations at the upper end of each range (Ø columns use that size); use the calculator for the exact size. — : not defined by ISO 286 for that size. Upper/Lower (mm) and inch columns are shown on wider screens.

About c11

c11 denotes a shaft tolerance zone with large clearance deviation in the ISO 286 system. It is used in H11/c11 (Large clearance for parts that must assemble easily despite dirt, heat or poor alignment: agricultural machinery, brake linkages, loose pulleys.).

At Ø25 mm c11 is −0.110 / −0.240 mm, i.e. 24.760 to 24.890 mm.

How the limits are calculated

c11 uses grade IT11 (a standard tolerance of 130 µm at 18–30 mm). Fundamental deviation: es is tabulated directly by ISO 286-1 Table 2; ei = es − IT11. See the fundamental deviation table for every letter. Values per ISO 286-1:2010.

Fits using c11

Related classes