h10 tolerance (shaft, IT10)

Shaft tolerance class h10 per ISO 286-1:2010: fundamental deviation es = 0, grade IT10 (40 µm at ≤ 3 mm to 250 µm at 400–500 mm). For an exact size, open the calculator with h10 selected.

Type
Shaft
Grade
IT10
Tolerance
40 … 250 µm
Fund. deviation
es = 0

h10 limits by size range

Size (mm)Upper (µm)Lower (µm)Ø max (mm)Ø min (mm)
≤ 30−403.0002.960
3 – 60−486.0005.952
6 – 100−5810.0009.942
10 – 140−7014.00013.930
14 – 180−7018.00017.930
18 – 240−8424.00023.916
24 – 300−8430.00029.916
30 – 400−10040.00039.900
40 – 500−10050.00049.900
50 – 650−12065.00064.880
65 – 800−12080.00079.880
80 – 1000−140100.00099.860
100 – 1200−140120.000119.860
120 – 1400−160140.000139.840
140 – 1600−160160.000159.840
160 – 1800−160180.000179.840
180 – 2000−185200.000199.815
200 – 2250−185225.000224.815
225 – 2500−185250.000249.815
250 – 2800−210280.000279.790
280 – 3150−210315.000314.790
315 – 3550−230355.000354.770
355 – 4000−230400.000399.770
400 – 4500−250450.000449.750
450 – 5000−250500.000499.750

Deviations at the upper end of each range (Ø columns use that size); use the calculator for the exact size. — : not defined by ISO 286 for that size. Upper/Lower (mm) and inch columns are shown on wider screens.

About h10

h10 denotes a shaft tolerance zone with zero line deviation in the ISO 286 system.

At Ø25 mm h10 is 0 / −0.084 mm, i.e. 24.916 to 25.000 mm.

How the limits are calculated

h10 uses grade IT10 (a standard tolerance of 84 µm at 18–30 mm). Fundamental deviation: es = 0: the tolerance zone sits entirely below the nominal size, and IT10 sets its width. See the fundamental deviation table for every letter. Values per ISO 286-1:2010.