m6 tolerance (shaft, IT6)

Shaft tolerance class m6 per ISO 286-1:2010: fundamental deviation ei +2 … +23, grade IT6 (6 µm at ≤ 3 mm to 40 µm at 400–500 mm). For an exact size, open the calculator with m6 selected.

Type
Shaft
Grade
IT6
Tolerance
6 … 40 µm
Fund. deviation
ei +2 … +23 µm

m6 limits by size range

Size (mm)Upper (µm)Lower (µm)Ø max (mm)Ø min (mm)
≤ 3+8+23.0083.002
3 – 6+12+46.0126.004
6 – 10+15+610.01510.006
10 – 14+18+714.01814.007
14 – 18+18+718.01818.007
18 – 24+21+824.02124.008
24 – 30+21+830.02130.008
30 – 40+25+940.02540.009
40 – 50+25+950.02550.009
50 – 65+30+1165.03065.011
65 – 80+30+1180.03080.011
80 – 100+35+13100.035100.013
100 – 120+35+13120.035120.013
120 – 140+40+15140.040140.015
140 – 160+40+15160.040160.015
160 – 180+40+15180.040180.015
180 – 200+46+17200.046200.017
200 – 225+46+17225.046225.017
225 – 250+46+17250.046250.017
250 – 280+52+20280.052280.020
280 – 315+52+20315.052315.020
315 – 355+57+21355.057355.021
355 – 400+57+21400.057400.021
400 – 450+63+23450.063450.023
450 – 500+63+23500.063500.023

Deviations at the upper end of each range (Ø columns use that size); use the calculator for the exact size. — : not defined by ISO 286 for that size. Upper/Lower (mm) and inch columns are shown on wider screens.

About m6

m6 denotes a shaft tolerance zone with tight transition deviation in the ISO 286 system. It is used in H7/m6 (Tighter than k6; parts that must not move under vibration but are still removable: bearing bushes, gears, couplings.).

At Ø25 mm m6 is +0.021 / +0.008 mm, i.e. 25.008 to 25.021 mm.

How the limits are calculated

m6 uses grade IT6 (a standard tolerance of 13 µm at 18–30 mm). Fundamental deviation: ei is tabulated directly by ISO 286-1 Table 2; es = ei + IT6. See the fundamental deviation table for every letter. Values per ISO 286-1:2010.