D11 tolerance (hole, IT11)

Hole tolerance class D11 per ISO 286-1:2010: fundamental deviation EI +20 … +230, grade IT11 (60 µm at ≤ 3 mm to 400 µm at 400–500 mm). For an exact size, open the calculator with D11 selected.

Type
Hole
Grade
IT11
Tolerance
60 … 400 µm
Fund. deviation
EI +20 … +230 µm

D11 limits by size range

Size (mm)Upper (µm)Lower (µm)Ø max (mm)Ø min (mm)
≤ 3+80+203.0803.020
3 – 6+105+306.1056.030
6 – 10+130+4010.13010.040
10 – 14+160+5014.16014.050
14 – 18+160+5018.16018.050
18 – 24+195+6524.19524.065
24 – 30+195+6530.19530.065
30 – 40+240+8040.24040.080
40 – 50+240+8050.24050.080
50 – 65+290+10065.29065.100
65 – 80+290+10080.29080.100
80 – 100+340+120100.340100.120
100 – 120+340+120120.340120.120
120 – 140+395+145140.395140.145
140 – 160+395+145160.395160.145
160 – 180+395+145180.395180.145
180 – 200+460+170200.460200.170
200 – 225+460+170225.460225.170
225 – 250+460+170250.460250.170
250 – 280+510+190280.510280.190
280 – 315+510+190315.510315.190
315 – 355+570+210355.570355.210
355 – 400+570+210400.570400.210
400 – 450+630+230450.630450.230
450 – 500+630+230500.630500.230

Deviations at the upper end of each range (Ø columns use that size); use the calculator for the exact size. — : not defined by ISO 286 for that size. Upper/Lower (mm) and inch columns are shown on wider screens.

About D11

D11 denotes a hole tolerance zone with running clearance deviation in the ISO 286 system.

At Ø25 mm D11 is +0.195 / +0.065 mm, i.e. 25.065 to 25.195 mm.

How the limits are calculated

D11 uses grade IT11 (a standard tolerance of 130 µm at 18–30 mm). Fundamental deviation: EI = −es of the same shaft letter; IT11 sets the width above EI. See the fundamental deviation table for every letter. Values per ISO 286-1:2010.